TM54 operational energy assessment to model realistic in-use performance — not just compliance benchmarks. Clear assumptions, practical recommendations, aligned with BREEAM.
Tell us about your project and we’ll respond within one working day.
SustainPlan delivers TM54 operational energy assessment UK-wide to model operational performance and support better decisions through design.
We agree realistic occupancy profiles, apply consistent assumptions, and produce results that guide design choices — not numbers benchmarked against an unreachable target.
BREEAM credits or planning requirements call for TM54 operational energy evidence.
You want to understand in-use energy performance, not just regulatory compliance outputs.
Your design team needs to test MEP and fabric options against realistic operational assumptions.
Regulated energy — the figure produced by SAP calculations or SBEM calculations — measures compliance against Part L of the Building Regulations, but it does not reflect how buildings actually perform in use. TM54 operational energy assessment uses CIBSE’s methodology to model the full energy demand of a building in operation, including unregulated loads such as plug-in equipment, lifts, small power, and catering. For schemes targeting net zero in operation, BREEAM Excellent or Outstanding ratings, or GLA policy compliance on actual carbon emissions, the TM54 operational energy assessment provides the only technically credible basis for the energy performance claim. It is increasingly expected by planning authorities, funders, and sustainability-focused clients as the standard of evidence for operational energy commitments.
"TM54 operational energy assessments for commercial and residential schemes UK-wide — modelling what buildings actually use, not just what compliance calculations assume."
TM54 uses dynamic simulation to model operational energy consumption across all end uses — lighting, small power, HVAC, hot water and lifts. This provides a realistic in-use picture that SAP and SBEM compliance calculations are not designed to give.
TM54 results depend heavily on occupancy profiles and operational schedules. We discuss realistic assumptions with the design team rather than applying generic defaults — producing a result the building can actually achieve.
Operational energy depends on how well controls, metering and commissioning strategies interact with the building systems. We model controls strategy scenarios so design decisions have a visible impact on the output.
TM54 is required for certain BREEAM energy credits. We produce outputs in the format required by the assessment and align with the credit tracker so modelling work contributes to certification, not just a standalone report.
Where the design team wants to test alternative MEP or fabric specifications against operational outcomes, we run comparison scenarios. This makes TM54 a decision-support tool rather than just a compliance deliverable.
Operational energy assumptions in TM54 feed into the operational carbon element of a whole life carbon assessment. We align both from consistent inputs to prevent the operational carbon figure from being derived from two different energy models.
Three entry points depending on where you are in the programme. No unnecessary scope, no gaps.
For: For projects where TM54 is required specifically to support BREEAM energy credit calculations.
You receive: TM54 assessment with BREEAM credit input summary and aligned credit tracker notes.
For: For projects where TM54 needs to inform MEP and fabric decisions as well as satisfy compliance requirements.
You receive: Full TM54 assessment — realistic occupancy modelling, design option testing and recommendations.
For: For projects where TM54 operational energy outputs need to feed directly into a whole life carbon assessment.
You receive: Joined-up TM54 and whole life carbon package with consistent operational energy assumptions.
SustainPlan provides TM54 operational energy assessments for architects, developers and building services engineers on commercial schemes where realistic in-use energy modelling is required.
Most commonly used where BREEAM credits, planning conditions or client sustainability targets call for evidence beyond SAP and SBEM compliance outputs.
Commission at RIBA Stage 3 or 4, once systems strategy is defined but before MEP design is fixed. Commissioning at Stage 2/3 allows TM54 to inform systems and controls decisions rather than just confirm them — which is where the design value sits.
Confirm methodology, occupancy profiles, BREEAM requirements and any design options to test.
Collect floor plans, systems specification and operational schedules.
Build TM54 model with agreed assumptions and produce baseline operational energy outputs.
Where options are required, run scenarios and present comparison results.
Issue assessment with BREEAM input summary and design recommendations.
The cost of getting it wrong — and the value of getting it right.
Late changes are expensive because they hit multiple parties at once: rework to drawings, re-coordination between disciplines, re-pricing, and potentially delayed approvals or sign-off. Even when a single change looks small, it can cascade into other systems (plant sizing, duct routes, risers, penetrations, controls, or acoustic/fire requirements).
Our approach is to treat the building as one system. We sequence decisions so that early work reduces downstream risk. This is where SustainPlan adds value beyond a transactional deliverable: we help you choose the right work at the right time, and we coordinate how it all fits together.
TM54 operational energy assessment models operational performance using realistic assumptions to inform better decisions.
Yes—SBEM calculations are compliance modelling; TM54 focuses on operational performance outcomes.
Ideally early enough to influence MEP decisions and operational strategy.
Operational intent/use profiles, drawings/areas, MEP assumptions and deadlines.
Yes—where scoped, we can test scenarios tied to specific decisions (not endless variants).
A single deliverable can solve today’s problem, but planning and compliance risk often appears later. These examples show how clients bundle services to protect programme, cost and design flexibility.
We provide compliance services across the planning and Building Control lifecycle, from early project advice through to final sign-off. The services above are common requirements, but more complex projects may need a more consultative approach. If you’re unsure what applies, use the options below to book a call, request a call back, or send us your project details.
Start a conversation and we’ll map your pathway from feasibility and planning through to compliance support and sign-off.
Our experienced consultants are all members of relevant trade accreditation schemes, including Elmhurst Energy, IES, and ECMK, to name a few. We pride ourselves on being one of the UK’s leading sustainability and energy consultancies, providing expertise in complex building compliance.





SustainPlan Ltd
71-75 Shelton Street, Covent Garden, London, United Kingdom, WC2H 9JQ
0333 772 0140
info@sustainplan.co.uk
Terms & Conditions | Privacy Statement | Sitemap | SustainPlan Company number 17085854.
Website by rockhopperdigital.co.uk