PSI-Value Calculations — Accurate Thermal Bridging for Better Compliance Outputs

PSI-value calculations to quantify junction thermal bridging — improve modelling accuracy in SAP and SBEM and flag buildability risks before they affect performance.

Start the conversation

Tell us about your project and we’ll respond within one working day.

Upload any plans or drawings.

SustainPlan provides PSI-value calculations UK-wide to quantify junction thermal bridging and improve modelling accuracy in SAP and SBEM.

We work from your drawings and details to produce consistent values — flagging buildability issues early so specification decisions are based on realistic performance assumptions.

You need this if...

Your SAP or SBEM model is using default Appendix K values that inflate the compliance penalty. 

Junctions in your build-up are non-standard and need project-specific analysis. 

You want thermal bridging assumptions that are consistent across all compliance outputs.

Thermal bridging at construction junctions is one of the largest sources of inaccuracy in the energy models used for Part L compliance, SAP calculations, and SBEM calculations. Using Appendix K default values instead of calculated PSI values consistently overestimates heat loss and understates energy performance — resulting in SAP calculations or SBEM calculations that are harder to pass and specifications that are more expensive than necessary. Calculated PSI values for standard and non-standard junctions remove this uncertainty, improve modelling accuracy, and reduce the risk of buildability issues on site. SustainPlan produces PSI value calculations from your architectural details — with outputs directly formatted for input into SAP calculations and SBEM calculations software.

What the scope covers?

"PSI-value calculations for new builds and refurbishments across the UK — improving SAP and SBEM accuracy and flagging thermal bridging risks before they reach site."

What you get

What we need from you

Technical deep dive

01

Project-Specific vs Appendix K Values

Appendix K default PSI values are conservative and often inflate the compliance penalty compared to project-specific calculations. Where junctions are well-detailed, project-specific PSI values improve accuracy and reduce unnecessary compliance risk.

02

Junction Detail Analysis

We work from your construction details to calculate PSI values for each junction type — wall/floor, window/wall, roof/wall and others. Results are traceable to the drawings they came from.

03

SAP and SBEM Integration

PSI values feed directly into the thermal bridging input in SAP and SBEM models. We align calculations with compliance modelling inputs so a change to one junction is reflected correctly across all compliance outputs.

04

Buildability and Detailing Flags

Some junction details perform well on paper but are difficult to achieve on site. We flag detailing risks alongside thermal performance results so specification and on-site delivery remain aligned.

05

Condensation Risk Alignment

Thermal bridges create local surface temperature depressions that can cause condensation and mould. Where condensation risk analysis is also required, we align thermal bridging and condensation outputs from consistent inputs.

06

Non-Standard and Retrofit Junctions

For non-standard build-ups, complex geometries or retrofit projects where existing junctions are being modified, we provide project-specific calculations that generic default values cannot represent accurately.

Scope options — choose what fits your stage

Three entry points depending on where you are in the programme. No unnecessary scope, no gaps.

Option A

Standard Residential Package

For: For new-build residential schemes where a standard set of junctions needs analysis to improve SAP accuracy over Appendix K defaults.

You receive: PSI values for standard junction set with SAP input summary and buildability notes.

Option B - Most Common

Full Junction Set with Coordination

For: For projects where all junctions need analysis and PSI values must be consistently aligned with SAP, SBEM and U-value calculations.

You receive: Full PSI-value package — all junctions, cross-referenced with compliance modelling inputs.

Option C

Non-Standard or Retrofit Junctions

For: For projects with complex or non-standard junctions, or retrofit schemes modifying existing junction details.

You receive: Project-specific analysis for non-standard junctions with condensation alignment where required.

Not sure whether project-specific PSI values are cost-effective for your scheme?

Who it's for and when to use it

Who it’s for:

SustainPlan provides PSI-value calculations for architects, building physicists and developers whose schemes have non-standard junctions or where Appendix K default values are creating unnecessary compliance penalties.

Most commonly commissioned alongside SAP or SBEM modelling.

Best timing:

Commission at RIBA Stage 3 or 4, once junction construction details are defined but before SAP or SBEM modelling is finalised.

Late commissioning is possible but may require modelling to be revisited if PSI values change compliance outcomes materially.

Our process

1

Triage call

Confirm junction types, existing compliance model status and what PSI values must demonstrate.

2

Detail review

Collect construction details and assess which junctions need project-specific analysis.

3

Calculations

Model each junction and produce PSI values with documentation and buildability notes.

4

SAP/SBEM integration

Deliver inputs in a format aligned to the compliance model and review alignment.

5

Coordination

Respond to queries and align with condensation risk analysis where required.

Why this matters commercially

The cost of getting it wrong — and the value of getting it right.

The cost of getting it wrong

Late changes are expensive because they hit multiple parties at once: rework to drawings, re-coordination between disciplines, re-pricing, and potentially delayed approvals or sign-off. Even when a single change looks small, it can cascade into other systems (plant sizing, duct routes, risers, penetrations, controls, or acoustic/fire requirements).

The benefit of a joined-up approach

Our approach is to treat the building as one system. We sequence decisions so that early work reduces downstream risk. This is where SustainPlan adds value beyond a transactional deliverable: we help you choose the right work at the right time, and we coordinate how it all fits together.

FAQs

If you want the best outcome, start with a package

A single deliverable can solve today’s problem, but planning and compliance risk often appears later. These examples show how clients bundle services to protect programme, cost and design flexibility.

We provide compliance services across the planning and Building Control lifecycle, from early project advice through to final sign-off. The services above are common requirements, but more complex projects may need a more consultative approach. If you’re unsure what applies, use the options below to book a call, request a call back, or send us your project details.

Where this service fits
SustainPlan supports projects across all four stages — here’s where this service fits.Stage 2 of 4 — Design & Compliance

Let's Work Together

Start a conversation and we’ll map your pathway from feasibility and planning through to compliance support and sign-off.