PSI-value calculations to quantify junction thermal bridging — improve modelling accuracy in SAP and SBEM and flag buildability risks before they affect performance.
Tell us about your project and we’ll respond within one working day.
SustainPlan provides PSI-value calculations UK-wide to quantify junction thermal bridging and improve modelling accuracy in SAP and SBEM.
We work from your drawings and details to produce consistent values — flagging buildability issues early so specification decisions are based on realistic performance assumptions.
Your SAP or SBEM model is using default Appendix K values that inflate the compliance penalty.
Junctions in your build-up are non-standard and need project-specific analysis.
You want thermal bridging assumptions that are consistent across all compliance outputs.
Thermal bridging at construction junctions is one of the largest sources of inaccuracy in the energy models used for Part L compliance, SAP calculations, and SBEM calculations. Using Appendix K default values instead of calculated PSI values consistently overestimates heat loss and understates energy performance — resulting in SAP calculations or SBEM calculations that are harder to pass and specifications that are more expensive than necessary. Calculated PSI values for standard and non-standard junctions remove this uncertainty, improve modelling accuracy, and reduce the risk of buildability issues on site. SustainPlan produces PSI value calculations from your architectural details — with outputs directly formatted for input into SAP calculations and SBEM calculations software.
"PSI-value calculations for new builds and refurbishments across the UK — improving SAP and SBEM accuracy and flagging thermal bridging risks before they reach site."
Appendix K default PSI values are conservative and often inflate the compliance penalty compared to project-specific calculations. Where junctions are well-detailed, project-specific PSI values improve accuracy and reduce unnecessary compliance risk.
We work from your construction details to calculate PSI values for each junction type — wall/floor, window/wall, roof/wall and others. Results are traceable to the drawings they came from.
PSI values feed directly into the thermal bridging input in SAP and SBEM models. We align calculations with compliance modelling inputs so a change to one junction is reflected correctly across all compliance outputs.
Some junction details perform well on paper but are difficult to achieve on site. We flag detailing risks alongside thermal performance results so specification and on-site delivery remain aligned.
Thermal bridges create local surface temperature depressions that can cause condensation and mould. Where condensation risk analysis is also required, we align thermal bridging and condensation outputs from consistent inputs.
For non-standard build-ups, complex geometries or retrofit projects where existing junctions are being modified, we provide project-specific calculations that generic default values cannot represent accurately.
Three entry points depending on where you are in the programme. No unnecessary scope, no gaps.
For: For new-build residential schemes where a standard set of junctions needs analysis to improve SAP accuracy over Appendix K defaults.
You receive: PSI values for standard junction set with SAP input summary and buildability notes.
For: For projects where all junctions need analysis and PSI values must be consistently aligned with SAP, SBEM and U-value calculations.
You receive: Full PSI-value package — all junctions, cross-referenced with compliance modelling inputs.
For: For projects with complex or non-standard junctions, or retrofit schemes modifying existing junction details.
You receive: Project-specific analysis for non-standard junctions with condensation alignment where required.
SustainPlan provides PSI-value calculations for architects, building physicists and developers whose schemes have non-standard junctions or where Appendix K default values are creating unnecessary compliance penalties.
Most commonly commissioned alongside SAP or SBEM modelling.
Commission at RIBA Stage 3 or 4, once junction construction details are defined but before SAP or SBEM modelling is finalised.
Late commissioning is possible but may require modelling to be revisited if PSI values change compliance outcomes materially.
Confirm junction types, existing compliance model status and what PSI values must demonstrate.
Collect construction details and assess which junctions need project-specific analysis.
Model each junction and produce PSI values with documentation and buildability notes.
Deliver inputs in a format aligned to the compliance model and review alignment.
Respond to queries and align with condensation risk analysis where required.
The cost of getting it wrong — and the value of getting it right.
Late changes are expensive because they hit multiple parties at once: rework to drawings, re-coordination between disciplines, re-pricing, and potentially delayed approvals or sign-off. Even when a single change looks small, it can cascade into other systems (plant sizing, duct routes, risers, penetrations, controls, or acoustic/fire requirements).
Our approach is to treat the building as one system. We sequence decisions so that early work reduces downstream risk. This is where SustainPlan adds value beyond a transactional deliverable: we help you choose the right work at the right time, and we coordinate how it all fits together.
PSI-value calculations quantify junction thermal bridging so compliance modelling is more accurate.
Often yes—PSI-values refine thermal bridging assumptions used in SAP calculations.
When junction intent is clear enough to define scope but early enough to influence detailing.
Junction details, build-ups, and which junctions are in scope.
Yes—U-value calculations cover fabric elements; PSI-values cover junction effects.
A single deliverable can solve today’s problem, but planning and compliance risk often appears later. These examples show how clients bundle services to protect programme, cost and design flexibility.
We provide compliance services across the planning and Building Control lifecycle, from early project advice through to final sign-off. The services above are common requirements, but more complex projects may need a more consultative approach. If you’re unsure what applies, use the options below to book a call, request a call back, or send us your project details.
Start a conversation and we’ll map your pathway from feasibility and planning through to compliance support and sign-off.
Our experienced consultants are all members of relevant trade accreditation schemes, including Elmhurst Energy, IES, and ECMK, to name a few. We pride ourselves on being one of the UK’s leading sustainability and energy consultancies, providing expertise in complex building compliance.





SustainPlan Ltd
71-75 Shelton Street, Covent Garden, London, United Kingdom, WC2H 9JQ
0333 772 0140
info@sustainplan.co.uk
Terms & Conditions | Privacy Statement | Sitemap | SustainPlan Company number 17085854.
Website by rockhopperdigital.co.uk