Post Occupancy Evaluation — Measure What Actually Happened

Measure how buildings actually perform in use — identify gaps between design intent and operational reality, and turn findings into improvements and lessons for the next project.

Start the conversation

Tell us about your project and we’ll respond within one working day.

Upload any plans or drawings.

SustainPlan delivers UK-wide post occupancy evaluation (POE) to capture how buildings perform in real operation.

We identify gaps between design intent and actual performance, surface practical improvements for facilities teams, and produce clear reports that close the feedback loop and inform better design decisions.

You want to know whether the building is performing as designed and what to do if it is not. 

BREEAM certification, a client brief or planning condition requires post occupancy evidence. 

You want to learn from this building’s performance to improve the next project.

Post-occupancy evaluation closes the gap between design intent and operational performance — identifying why a building performs differently in use from how it was modelled and what interventions will bring it back into line. The performance gap between design-stage SAP calculations or TM54 operational energy assessment predictions and measured energy use is well documented, and in many cases is significant.

SustainPlan carries out post-occupancy evaluations that combine occupant feedback with metered energy data, building management system analysis, and targeted monitoring to diagnose the root causes of underperformance. Outputs feed directly into operational improvements, building manual updates, and future-project learning for design teams and developers seeking to close the gap between modelled and actual energy performance.

What the scope covers?

"Post occupancy evaluations for commercial and residential schemes across the UK — closing the gap between what was designed and what buildings actually deliver."

What you get

What we need from you

Technical deep dive

01

Performance Gap Analysis

We compare actual in-use performance against design intent — energy consumption, internal temperatures, ventilation rates and occupant comfort. The gap between assumed and actual performance is where most improvement opportunities sit.

02

Energy Consumption Review

We review metered energy data and compare it against design-stage modelling assumptions. Where consumption is significantly higher than predicted, we identify the most likely causes and prioritise investigation.

03

Comfort and Indoor Environment Assessment

Thermal comfort, air quality, acoustics and daylighting all affect building usability. We assess indoor environment quality through data review and occupant survey so operational issues are identified rather than assumed.

04

Systems and Controls Evaluation

Buildings often underperform because controls are not set up correctly or because commissioning assumptions did not survive handover. We assess whether systems are operating as designed or whether controls require adjustment.

05

Occupant Satisfaction Survey

Occupant feedback provides evidence that cannot be captured through metered data alone. We design and run structured surveys that produce comparable data and highlight issues that are invisible in energy consumption figures.

06

Lessons Learned for Future Projects

POE findings are most valuable when they inform the next project. We structure the lessons learned output so it is useful to architects, engineers and clients making decisions on similar buildings.

Scope options — choose what fits your stage

Three entry points depending on where you are in the programme. No unnecessary scope, no gaps.

Option A

Rapid POE

For: For projects needing a light-touch performance review — energy data, brief occupant survey and key findings.

You receive: Rapid POE report with performance summary and priority improvement actions.

Option B - Most Common

Full POE

For: For projects where a comprehensive evaluation of energy, comfort and systems performance is required.

You receive: Full POE — performance gap analysis, occupant survey, improvement recommendations and lessons learned.

Option C

BREEAM or Client-Required POE

For: For projects where POE is a BREEAM credit requirement or a client or planning condition.

You receive: POE delivered to the required evidence standard with BREEAM credit inputs where applicable.

Want to know how your building is actually performing?

Who it's for and when to use it

Who it’s for:

SustainPlan provides post occupancy evaluation for architects, developers, facility managers and building owners.

Most commonly used 12-18 months after handover when the building has been in operation long enough to produce meaningful performance data.

Best timing:

Commission 12-18 months after practical completion, once the building has settled into normal operation and occupants have experience with the building’s performance across different seasons.

Earlier commissioning is possible for rapid POE where prompt feedback is needed.

Our process

1

Scope and data gathering

Confirm evaluation scope, access to energy data and occupant contact list.

2

Performance data review

Analyse energy consumption and compare against design-stage assumptions.

3

Occupant survey

Design and run structured survey to capture comfort and environment feedback.

4

Gap analysis

Identify performance gaps and diagnose likely causes.

5

Report and recommendations

Deliver POE report with improvement actions and lessons learned.

Why this matters commercially

The cost of getting it wrong — and the value of getting it right.

The cost of getting it wrong

Late changes are expensive because they hit multiple parties at once: rework to drawings, re-coordination between disciplines, re-pricing, and potentially delayed approvals or sign-off. Even when a single change looks small, it can cascade into other systems (plant sizing, duct routes, risers, penetrations, controls, or acoustic/fire requirements).

The benefit of a joined-up approach

Our approach is to treat the building as one system. We sequence decisions so that early work reduces downstream risk. This is where SustainPlan adds value beyond a transactional deliverable: we help you choose the right work at the right time, and we coordinate how it all fits together.

FAQs

If you want the best outcome, start with a package

A single deliverable can solve today’s problem, but planning and compliance risk often appears later. These examples show how clients bundle services to protect programme, cost and design flexibility.

We provide compliance services across the planning and Building Control lifecycle, from early project advice through to final sign-off. The services above are common requirements, but more complex projects may need a more consultative approach. If you’re unsure what applies, use the options below to book a call, request a call back, or send us your project details.

Where this service fits
SustainPlan supports projects across all four stages — here’s where this service fits.Stage 4 of 4 — Handover & Existing Buildings

Let's Work Together

Start a conversation and we’ll map your pathway from feasibility and planning through to compliance support and sign-off.